Multi Function Testers 6015

Multi Function Testers 6015

IEC 61010-1 CAT.III 300V

The top of the range KEW6015 can perform TEN separate test functions and provides all the test functions generally required to verify the safety of electrical installations in full compliance with IEC61557.
The KEW6015 can store test results in its on-board memory for later downloading to a computer or printer.
Data can be downloaded via the infra Red Communication Port (IRDA Port).
The KEW6015 is software driven and guides the user through the test functions required making the instrument very easy to use.
It's numerous features include the ability to conduct 3 or 4 wire earth resistance test,
D-Lok technology to prevent tripping of most passive type RCD's when loop testing and mains voltage and frequency measurement.

  1. Live circuit and wiring connection check LED’s
  2. D-Lok technology on loop test range
  3. On-board memory to store test results
  4. Downloading of data via IRDA port
  5. Auto power off
  6. Back light display
  7. Polarity switch
  8. Continuity Auto-null
  9. Auto ramp and auto test on RCD ranges
  10. Test of a large kind of RCD's: Standard, Selective, AC and A
    (DC sensitive breakers)
  11. Designed to IP54 Rating
  12. Complies with IEC61557
     

Continuity Testing
Measuring Ranges 20/200/2000Ω Autoranging
Open Circuit Voltage >6V
Short Circuit Current >200mA DC
Accuracy |±(1.5%rdg+3dgt)
Loop Impedance Testing
Rated Voltage 230V AC ±10% [50Hz]
Voltage Measuring Range 100~400V AC [50Hz]
Impedance Ranges 20/200/2000Ω
Nominal Test Current 25A (20Ω range) 1.2A (200Ω range) 1.2A (2000Ω range)
Test Period 1/2 cycle (10ms)
Base Accuracy 20Ω range
|±(2%rdg+2dgt) D-LOK OFF
|±(5%rdg+5dgt) D-LOK ON
RCD Testing
Rated Voltage 230V AC ±10% [50Hz]
Trip Current Settings RCD × 1/2 : 10,30,100,300,500,1000mA
RCD × 1 : 10,30,100,300,500,1000mA
RCD × 5 : 10,30,100mA
Trip Current Duration RCD × 1/2 × 1: 2000ms
RCD × 5: 200ms fast trip 50ms
Accuracy Trip current +10%-0%
of test current at 230V Trip time±(2%rdg + 3dgt)
Insulation Testing
Measuring Ranges 20/200/2000MΩ Autoranging
Test Voltage 250V, 500Vand 1000V DC
Output Voltage on
Open Circuit
250V+20%-0%
500V+20%-0%
1000V+20%-0%
Rated Current >1mA
Accuracy 0~100MΩ|±(2%rdg+3dgt)
100MΩ~2000MΩ|±(5%rdg+4dgt)
PSC Testing
Rated Voltage 230V AC ±10% [50Hz]
PSC Ranges 2000A and 20kA
Accuracy PSC accuracy derived from measured
loop impedance specification and measured
voltage specification
Fault Current
Rated Voltage 230V AC ±10% [50Hz]
Fault Current Ranges 2000A and 20kA
Nominal Test Current 1.2A(2000A) 25A(20kA)
Accuracy Fault Current accuracy derived from measured loop impedance specification and measured voltage specification
Earth Resistance
Ranges 20Ω/200Ω/2000Ω
Output Voltage 50V peak to peak square wave
Frequency 720Hz ±5%
Accuracy 20Ω|±(2%rdg+5dgt)
200/2000Ω|±(2%rdg+3dgt)
General
Safety Standard IEC61010-1 CAT.III 300V Pollution Degree 2
Withstand Voltage 3700V AC for 1 minute
Power Source 8 × 1.5V R6 or LR6
Dimensions 105(L) × 210(W) × 240(D)mm
Weight 1924g approx.
Accessories
7098 (Distribution board test leads for Loop/PSC/RCD testing )
7099 (Moulded plug test leads(1 set) for Loop and RCD testing at sockets(EU plug) )*
7025 (Lead for insulation and continuity testing)
7109 (Earth resistance test leads (1 set))
KSLP5 (external earth probe)
8032 (auxiliary earth spikes)
8210 (IrDA Adaptor)
Durable Holdall
Accessory pouch
Battery 8 × 1.5V R6 or LR6
Instruction Manual
*7112:(Moulded plug test leads (1set) for Loop and RCD testing at sockets (UK plug) )

7113:(Moulded plug test leads (1set) for Loop and RCD testing at sockets (AU plug)

7114:(Moulded plug test leads (1set) for Loop and RCD testing at sockets (SA plug) )

  • 相关文章:

发表评论:

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。

日历

最新评论及回复

最近发表

Powered By Z-Blog 1.8 Spirit Build 80605

沪ICP备08022410号Copyright 2008-2010 君达仪器博客. Some Rights Reserved.